Your documents basket contains 0 items
| Operating voltage | 230 V AC |
| Frequency | 50 - 60 Hz |
| Number of channels | 1 |
| Installation type | Front panel installation/wall installation |
| Type of connection | Screw terminals |
| Program | Daily program |
| Power reserve | 3 days full power reserve approx. 3 days after connection to operating voltage |
| Switching capacity at 250 V AC, cos φ = 1 | 10 A |
| Switching capacity at 250 V AC, cos φ = 0,6 | 2 A |
| Shortest switching times | 30 min, 12 h |
| Programmable every | 15 min, 12 h |
| Time accuracy at 25 °C | ≤ ± 1 s/day (quartz) |
| Type of contact | Changeover contact |
| Switching output | Potential-free and phase-independent |
| Stand-by consumption | ~0.5 W |
| Test approval | EMV |
| Housing and insulation material | High-temperature resistant, self-extinguishing thermoplastic |
| Type of protection | IP 20 |
| Protection class | II according to EN 60 730-1 |
| Ambient temperature | -10°C ... 55°C |
| Tender text | DOC | SUL-189-hw_1890108 (22,5 kB) |
| Operating instructions | SYN-169-hw_SUL-189-hw (391,8 kB) | |
| Data sheet | SUL 189 hw (492,7 kB) |
Your documents basket contains 0 items