LUNA 112 top2 AL

Description

  • Light level controller
  • External light sensor included in delivery
  • 2 channels
  • 2 external contol inputs
  • Channel-independent operating hour counter
  • Switching brightness digitally adjustable
  • Adjustable On and Off switching delay
  • to avoid switching errors caused by lightninh, car headlights etc. Preset 1 minute
  • Switching brightness and switching delay can be set separately for switching On and Off
  • Onscreen display of channel and switching status as well as current lux value
  • DuoFix spring terminals
  • for 2 conductors per connection terminal
  • Zero-cross switching for relay-saving switching and high lamp loads (not with 24 V devices)
  • Up to 4 sensors can be attached
  • Up to 10 devices can be connected to a digital sensor
  • Interface for OBELISK top2 memory card (PC programming)
  • 2. insertable switching program
  • Copying programs
  • Storing programs
  • External light sensor included in delivery
  • Extended brightness range
  • Permanent switching ON/OFF
  • Test function
  • (Permanent ON) to check the installation independently of set brightness value
  • Switching preselection
  • Display back light (can be turned off)
  • PIN coding
  • External input
  • for switches or buttons
  • Operating hour counter
  • with reminder function

Technical data

Operating voltage 100 – 240 V AC
Frequency 50 – 60 Hz
Number of channels 2
External inputs 2
Stand-by consumption 1,3 W
Setting range brightness 1 – 99000 lx
Preset brightness value 15 lx
Switch-on delay 0 – 59 min
Switch-off delay 0 – 59 min
Type of contact 2 two-way changeover contacts
Switching output Potential-free, not for SELV
Width 3 modules
Installation type DIN rail
Type of connection DuoFix spring terminals
Keyboards 4 touch buttons
Switching capacity

16 A (at 250 V AC, cos φ = 1), 10 A (at 250 V AC, cos φ = 0.6), 10 AX (Fluorescent lamp load)

Switching capacity min. ca. 10 mA
Incandescent lamp load 2600 W
Halogen lamp load 2600 W
Fluorescent lamp load (conventional) not corrected 2300 VA
Fluorescent lamp load (conventional) series-corrected 2300 VA
Fluorescent lamp load (conventional) lead-lag circuit 2300 VA
Fluorescent lamp load (conventional) parallel-corrected 800 VA 80 µF
energy saving lamps 22 x 7 W, 18 x 11 W, 16 x 15 W, 16 x 20 W, 14 x 23 W
Fluorescent lamp load (electronic ballast) 650 VA
Test approval VDE
Housing and insulation material High-temperature resistant, self-extinguishing thermoplastic
Ambient temperature -30 °C … +55 °C
Type of protection IP 20, sensor IP 55
Protection class II, Sensor III
Max. cable length to sensor 100 m

Connection example

LUNA 112 top2 AL

Scale drawings

LUNA 112 top2 AL

Downloads

Format Download
Operating instructions PDF
Tender texts DOC
Software ZIP

Variants

Article number Data sheet Documents basket
LUNA 112 top2 EL - Light level controller

LUNA 112 top2 EL

1120200
more
LUNA 112 top2 AL - Light level controller

LUNA 112 top2 AL

  • Surface-mounted light sensor
Article number 1120100
Data sheet
Documents basket